Ventilation strategies
As for living comfort at the levels of airtightness we are building to, it becomes necessary to use a whole house ventilation system. For this there are two main options; Mechanical Extract Ventilation (MEV) and Mechanical Ventilation with Heat Recovery (MVHR).
MEV uses a constantly operating fan which extracts warm moist air from the warm moist rooms (ie. bathrooms, kitchen etc) via ductwork, with fresh air effectively being sucked in via trickle vents and gaps in the structure. MEV is fairly economic to install, especially as it eliminates the need for dedicated extractors in the bathrooms. However, for very airtight buildings additional openings in the structure need to be introduced and warm stale air is replaced with fresh but cold air, thus driving heat out of the building and reducing its efficiency. As an aside to this, an MEV option is available for our heat pump which actually uses the heat from the outgoing stale warm air to pre-heat the ‘brine’ before it goes into the heat pump, thus recovering some of that energy. This is a great idea and an option well worth considering for self builders opting for a heat pump, but we eliminated it on the basis that that our first floor is largely unheated and such a system might lead to the cooling of that area via the trickle vents in the Velux windows which would need to be open for this system to work properly.
MVHR combines MEV with an intake system which supplies the ‘dry’ rooms with fresh air, preheated via a heat exchanger which takes heat from the extracted air. This is the system we have chosen, a (claimed) 95% efficient unit made by Dutch company Renovent and supplied by Ubbink in the UK. The unit has three settings and is virtually silent in operation. At the lowest setting (normal operation) it uses just half the power of a 60W light bulb and should be adequate to ‘heat’ the three first floor bedrooms alongside the heat convected from the ground floor. Other advantages are good air quality by using fresh, filtered air from outside, and the ability to use the unit to provide cooling in summer by bringing in cool air at night into a solar heated building.
Comments: 0 (Add)
Check Availability
Tags
animals architectural design awards, cottages, sustainability bees caravan cottages Curlew Cottage days out design dogs eastcambusmoon electric vehicles foundation fruit and veg production furniture gold award great review green toursim hard landscaping heat pump heat recovery hens holiday accommodation insulation interiors lambing landscaping loch lomond low energy measures national park nature outings owls people photoshoot roof solar PV timber frame Training ventilation walks website windows
Blog archive
- June 2019 (1 entry)
- February 2019 (1 entry)
- December 2018 (1 entry)
- November 2018 (1 entry)
- April 2018 (1 entry)
- December 2017 (1 entry)
- October 2017 (2 entries)
- June 2017 (1 entry)
- April 2017 (2 entries)
- March 2017 (1 entry)
- February 2017 (1 entry)
- February 2016 (1 entry)
- June 2014 (1 entry)
- June 2013 (1 entry)
- April 2013 (1 entry)
- February 2013 (1 entry)
- May 2012 (2 entries)
- April 2012 (1 entry)
- March 2012 (2 entries)
- December 2011 (1 entry)
- August 2011 (2 entries)
- June 2011 (4 entries)
- May 2011 (4 entries)
- April 2011 (1 entry)
- December 2010 (4 entries)
- October 2010 (2 entries)
- August 2010 (2 entries)
- December 2009 (1 entry)
- November 2009 (2 entries)
- October 2009 (2 entries)
- September 2009 (3 entries)
- August 2009 (1 entry)
- July 2009 (2 entries)
- June 2009 (3 entries)
- May 2009 (7 entries)
- April 2009 (2 entries)
- March 2009 (2 entries)
- February 2009 (1 entry)
- January 2009 (4 entries)
- December 2008 (2 entries)
- November 2008 (1 entry)
- June 2008 (5 entries)
- May 2008 (4 entries)
- April 2008 (11 entries)
- March 2008 (14 entries)
- February 2008 (9 entries)
- January 2008 (12 entries)
- December 2007 (11 entries)
- November 2007 (11 entries)
- October 2007 (10 entries)
- September 2007 (6 entries)